Strany 2 - Intentionally

10 4 Pre-Installation Requirements 4.1 Tools and Consumable MaterialTable 4-1 provides a consolidated list of the tools and consumable material whic

Strany 3 - Table of Contents

114 Pre-Installation Requirements Make sure the location allows sufficient space for movement of the arms in the extended condition.4.3.2 Site Envi

Strany 4

124 Pre-Installation Requirements4.3.3 Electrical Outlets & Requirements The mains outlet should have a good Ground connection. Grounding of th

Strany 5

134 Pre-Installation Requirements 4.7 Included System ComponentsFigure 7 shows the major components and accessories included with a wall mounted Int

Strany 6 - 1 Introduction

145 Installation of Intraskan DC 5 Installation Procedure SummaryThis section provides the instructions necessary to install the Wall Mounted Intrask

Strany 7 - 2 Safety and Precautions:

155 Installation of Intraskan DCFigure 11: Fix base unit rear cover along with power board.• Fix one M10X100 wood screw with M10 plane washer at the

Strany 8 - 2 Safety and Precautions

165 Installation of Intraskan DC• Fix the base unit rear cover along with power board assembly to the base unit plate with six M3x6 HSHC screws usin

Strany 9 - 3 Product Overview

175 Installation of Intraskan dc 5.2 Procedure for Input wiring:• Strip the insulation on each input wire for a length of approximately 5 mm. Using

Strany 10 - 4.3 Site Preparation

185 Installation of intraskan DC 5.3 Straight- Arm Installation:• Remove the circlip fixed to the straight-arm guide rod using circlip pliers as s

Strany 11

195 Installation of intraskan dc 5.4 Scissor Arm Installation • Remove the end cap by removing M3x6 self tapping CSK screws screw using screw drive

Strany 12

2This page is left blankIntentionally.

Strany 13

205 Installation of Intraskan dc 5.5 Scissor Arm Cables ConnectionLay cables flushed along the right inner side. Carefully pull any excess length an

Strany 14 - 5.1 Base Unit Mounting

215 Installation of Intraskan dc 5.6 Ground Connection Check:Using a Multimeter, check the continuity between the following points:-• Between Ground

Strany 15 - 5.1.2 Two Stud Mounting

225 Installation of Intraskan dcFigure 32: Wire routing hole & 2 mounting holesFigure 30-: 4 M3x6Hex socket head cap screwsFigure 31: Console cabl

Strany 16

235 Installation of intraskan dc 5.8 IntraskanDCConsolecongurations:Conguration-1:Can use Internal Console and Internal Exposure Switch.Congura

Strany 17

245 Installation of intraskan dcConguration-3:8P8C with door bell switch.Can use two Consoles with Internal Exposure Switch and double door bell swit

Strany 18

255 Installation of intraskan dcConguration-4:3 WIRE WITH SINGLE DOORBELL SWITCH.J1, J2 and J3 Open on External console PCB.Can use Internal Console

Strany 19

265 Installation of intraskan dcConguration-5:3 WIRE WITH DOUBLE DOORBELL SWITCHCan use Internal Console with Internal Exposure Switch and double doo

Strany 20

275 Installation of intraskan dcConguration-66P4C WITH SINGLE DOORBELL SWITCH.J1, J2 and J3 Open on External console extension PCB.Can use Internal C

Strany 21

285 Installation of intraskan dcConguration-76P4C WITH DOUBLE DOORBELL SWITCH.Can use Internal Console with Internal Exposure Switch and double door

Strany 22

295 Installation of intraskan dc 5.9 Baseunitcoverxing:• Take the base unit front cover and connect the console cable to the J5 connector on the

Strany 23

3Table of contents 1 Introduction ...

Strany 24 - 8P8C with door bell switch

305 Installation of intraskan dc 5.10 Scissor-Arm Operation CheckingMove the Scissor arm and ensure there is no drift as per steps given below.• Ke

Strany 25 - Conguration-4:

315 Installation of intraskan dcNote: For changing kV follow the steps given below:Restart the unit and while starting press the UP/Increment and DOWN

Strany 26 - Conguration-5:

325 Installation of intraskan dcStep 3:- • Keep the vertical arm in horizontal position and horizontal arm in vertical position as shown in the Fig-u

Strany 27 - Conguration-6

336 Console Interface 6 Console Interface 6.1 Console as a ToolThe control console of Intraskan DC stores information about the exposures delivered

Strany 28 - Conguration-7

346 Console InterfaceTable 6-4: Keyboard event flag bitmaskBit Position Description0 Exposure key stuck1~12 <unused>13 Set / Select / Mode key

Strany 29 - 5.9 Baseunitcoverxing:

35 7 Trouble shooting Techniques 7.1 Errors and WarningsWhen in a fault state, the unit would display an error message with a corresponding error co

Strany 30 - 5.13 X-Ray Tube Seasoning

367 Trouble ShootingTable 7-3: TROUBLE SHOOTING CHART (MECHANICAL)OBSERVED PROBLEM RECOMMENDED ACTION1. Scissor Arm is Drifting from its released posi

Strany 31 - 5.14 Mechanical Adjustments

37 8 Service Procedure 8.1 Replacement GuideTable 8-1: Replacement Parts listPart Failed Part to be replacedIf the Scissor Arm or parts of Scissor a

Strany 32

388 Service Procedure• Remove the 2 M3X16 self tapping pan head screws using phillips screw driver and remove the bottom cover as shown in the Figure

Strany 33 - 6 Console Interface

398. Service Procedure8.2.1.5 HV Tank removal • To remove the HV Tank from the clamp, remove the 5 (M3X6 Hex. socket button head) screws (from 1 to

Strany 34 - 6 Console Interface

4Table of Contents 8.2 Replacing the Scissor-Arm: ...

Strany 35 - 7 trouble shooting

408. Service Procedure8.2.1.6 Final Steps before Removal• Remove 2 bottom caps of the straight arm by removing M3x6 self tapping screws (2 screws fo

Strany 36 - 7 Trouble Shooting

418 Service Procedure8.2.2 Installing the New Scissor Arm8.2.2.1 Initial setup• Using gloves, apply grease to the new scissor-arm insertion rod and

Strany 37 - 8 Service Procedure

428 Service Procedure8.2.2.3 Scissor-arm cable connection: • Using a 2.5mm allen key connect the GND wires(Ring terminals) of both the Communication

Strany 38 - 8 Service Procedure

438 Service ProcedureFigure 62 • Route the INV power cable as shown in the Figure 62 and connect it to the sealing board 3 pin connector (Pin 1 &

Strany 39 - 8. Service Procedure

448 Service Procedure• Fix the rubber fixing ring on the positioning cone as shown in Figure 65 (1) and slide the rubber dial ring and fix it in the

Strany 40

458. Service Procedure 8.3 Replacing the Straight-Arm(Applicable for all length)Inverter cable(J1)Communica-tion cable(J2)Ground pointCable tiesFigu

Strany 41

468. Service Procedure• Remove the circlip of the straight arm as shown in Figure 73 and remove the straight arm from the base unit as shown in Figu

Strany 42

478. Service Procedure• Route the scissor-arm cables through the straight-arm till it comes inside the base unit (Use guide wire for routing and guid

Strany 43

488. Service Procedure 8.4 Replacing the Power Board8.4.1 Removing the Power Board• Execute the Steps in “8.2.1.1 Power Off:” above.• Execute the

Strany 44

498. Service Procedure8.4.2 Fixing the power board • Take the new power board (along with its plate) and fix it (ensure that J3 & J4 connectors

Strany 45

5Table of Contents8.16.1 Removing the Input Switch ...

Strany 46

508. Service Procedure 8.5 Replacing the tube head8.5.1 Removing the tube head• Perform the steps in "8.2.1.1 Power Off:".• Perform the

Strany 47

518. Service Procedure8.5.2 Fixing the new tube head• Take the HV-Tank and fix it to the clamp using the following sequence:-• Using 2.5mm allen ke

Strany 48

528. Service Procedure 8.6 Replacing the Control Board8.6.1 Removing the Control Board• Execute the Steps in “8.2.1.1 Power Off:”.• Execute the St

Strany 49

538. Service Procedure 8.7 Replacing the Control Console8.7.1 Removing the console assembly• Execute the Steps in “8.2.1.1 Power Off:” above.• Exe

Strany 50

54 8.10 Replacing the Scissor Arm cable harness8.10.1 Removing the Scissor arm cables• Execute the Steps in "8.2.1.1 Power Off:".• Execu

Strany 51

558.10.2 Assembly Steps for Scissor-Arm Cable• Hold the end of the Cable harness (Figure 94 ) and insert the communication wire (cable with connec-t

Strany 52

56• Keeping the cable length (towards the L-Clamp end) fixed, route the communication cable near the rotating bush (inside the outer hole of L Arm) a

Strany 53

57• Keeping the vertical arm in vertical position and horizontal arm in horizontal position, route the cable inside the horizontal arm such a way tha

Strany 54

588.10.3 Fixing the Scissor-Arm End caps• For fixing back the scissor-arm end caps first, align the rubber part of scissor-arm as shown in Figure 11

Strany 55

59 8.13 Replacement of Keypad console:8.13.1 Removing the Keypad console:• Execute the steps in “8.2.1.1 Power Off:”.• Pull out the console assemb

Strany 56

6Introduction 1 Introduction 1.1 About Intraskan DCThe Intraskan DC High Frequency Intraoral X-ray has been engineered and manufactured to provide m

Strany 57

60 8.14 Replacement of Doorbell switch:8.14.1 Removing the Door bell switch:• Execute the steps in “8.2.1.1 Power Off:”.• Pull out the Dummy Logo

Strany 58

61 8.16 Replacing the Input switch 8.16.1 Removing the Input Switch• Execute the Steps in "8.2.1.1 Power Off:".• Execute the steps in &q

Strany 59

62• Connect the “Live(Blue) and Neutral(Black) wires(Ring terminals) of switch” to the terminal block fixed on the power board clamp using phillips s

Strany 60

638.17.2 Fixing the new Input power cord• Take the new power cord which comes along with grommet assembly and separate the grommet as-sembly into th

Strany 61

64• Disconnect the console cable from the console board.• Fix back the new console cable on the console board.• Route the cable through the slot pr

Strany 62

65• Re-calibrate the Tube Head by performing the following procedure:• Cover X-ray outlet by lead cap.• Place the Power Switch to the ON position a

Strany 63

66• Switch OFF the power and wait till the Control Console is turned off. Remove the Dead Man Switch Connector Jig which is connected at the bottom o

Strany 64

67 10 Spare Parts ListS. No. Parts Order Code (with Packing Box)1 Tube Head SK3050004602 Tube Head Cover(Top and Bottom) SK3050004613 Control board

Strany 65

68© ImageWorks, Inc Copyright 2013 • Rev. A - October 2013

Strany 66 - 9.5 Disposal of the Unit

7Safety and Precautions Installation of the Intraskan DC must be done only by an authorized service engineer. Consult the factory or dealer as neces

Strany 67 - 10 Spare Parts List

82 Safety and Precautions 2.3 Labels on ProductRefer to User Manual for the list and location of each label used on the equipment. 2.2 Safety Symbol

Strany 68 - • Rev. A - October 2013

9 3 Product Overview 3.1 Intraskan DC System ComponentsTable 3.1. Intraskan DC System ComponentsDescriptionModelsAvailableIntraskan DC, FS05 , Wall