AE/LZB 119 1892 R1A
4
SPECIFICATIONS
GENERAL
AC Power Operating Voltage Range
100 — 127 and 200 — 240 Vac (auto 115/230 Vac selection)
AC Power Operating Frequency Range
47 — 63 Hz
AC Power Consumption
Complete Console System 375 watts maximum
Enhanced Audio Enclosure & Speakers 80 watts maximum
Personal Computer System (See manufacturer's specifications)
Temperature Range
(ambient air temperature)
Operating +50° to +104° Fahrenheit (+10° to +40° Celsius)
Storage -30° to +122° Fahrenheit (-34° to +50° Celsius)
Relative Humidity Range
Enhanced Audio Enclosure, Spkrs. & Disp. Keyboard
Operating 20% to 80%, non-condensing
Storage 10% to 90%, non-condensing
Personal Computer System (See manufacturer's specifications)
Dimensions
(height x width x depth; approximate)
Enhanced Audio Enclosure 3.25 x 15 x 9.8 inches (8.26 x 38.10 x 24.98 cm)
Speaker, Desk-Top (less volume knob) 6.38 x 6.25 x 3.69 (16.3 x 15.8 x 9.3 cm)
Speaker, Rack-Mount (less volume knob) 5.25 x 19 x 3.38 (13.34 x 48.26 x 8.59 cm)
Personal Computer System (See manufacturer's specifications)
Rack-Mount Height; Optional (EIA 19-inch std.)
Enhanced Audio Enclosure 2 rack units (3.5 inches / 8.89 cm)
Speaker 3 rack units (5.25 inches / 13.34 cm)
Weight
(approximate)
Enhanced Audio Enclosure 11.7 lbs. (5.31 Kg)
Enhanced Audio Enclosure w/ Rack Mount Option 14.0 lbs. (6.35 Kg)
Speaker, Desk-Top 2.1 lbs. (0.95 Kg)
Speaker, Rack-Mount with two Speaker Assemblies 4.2 lbs. (1.91 Kg)
Cabling (standard supplied) 6.0 lbs. (2.72 Kg)
Personal Computer System (see manufacturer's specifications)
Enhanced Audio Enclosure Case Construction
0.060-inch sheet metal construction capable of supporting up
to 80 pounds (36.3 kilograms) when free-standing on a flat
surface (not rack mounted)
REGULATORY
Power Supply Safety and Performance
115 Vac Operation Meets ANSI/UL 1950 and CSA C22.2 No. 950-M89 requirements
230 Vac Operation Meets EN 60950-1992 and BS 7002 requirements
Leased Line Interface
Meets UL 1459, IEC 950, EN 60950 and BS 7002 requirements
Radio Frequency Interference (RFI)
Meets EN 55022 and FCC Part 15 Class A requirements
Electro-Magnetic Immunity (EMI)
Meets IEC 801 Parts 2, 3 and 4 for ESD, radiated RF
immunity and power line bursts respectively
CONTROL DATA LINKS
CEC/IMC
⇔⇔
Personal Computer (PC)
9.6k or 19.2k baud RS-232 or RS-422 full-duplex serial
connection between the console's Personal Computer (PC) and
the Console Interface Module (CIM) within the CEC/IMC.
Full-duplex 4-wire data modems may be employed between
the PC and CIM in a remote console installation.
Personal Computer
⇔⇔
Enhanced Audio Enclosure
9600 baud RS-232 full-duplex serial connection
Enhanced Audio Enclosure
⇔⇔
Optional Equipment
RS-422 serial I/O port provided at rear panel of Enhanced
Audio Enclosure for control data interfacing to optional
equipment (for future expansion use)
*