The Omni constantly monitors the alarm zones and several internal
matters and will alert you if it detects trouble. The particular trouble is
indicated on the bottom line of the display and a trouble signal is given
by beeping the console beeper continuously, 2 beeps per second.
When any trouble condition occurs, the console will beep twice per
second and continue to beep until the ' * ' key (cancel) is pressed to
acknowledge the trouble. The console will say "TRBL NOW" (trouble
now) if the trouble condition actually exists while you are looking at
the console. It will say "HAD TRBL" (had trouble) if the trouble con-
dition occurred and then corrected itself.
The trouble indications and their meanings are shown below.
- ZONE NAME TRBL NOW or HAD TRBL: If the reading for
a zone becomes abnormal, trouble will be indicated on that zone -
See Status \ Test. Trouble on security zones is usually caused
by excessive resistance in the contact and wiring. If the cause is
not obvious, call your installer for service.
- AC POWER OFF TRBL NOW or HAD TRBL: Indicated if
the normal house current powering the Omni controller is
interrupted for more than 3 minutes. If this happens without good
cause, check the wall mounted transformer to ensure that it
hasn't come out of the wall socket; check to see that the socket has
power; check the MAIN fuse (F3) on the Omni controller to be
sure that it is good.
- BATTERY LOW TRBL NOW or HAD TRBL: Every hour,
the Omni makes a dynamic test of the battery. The charger is
turned off and a load is placed on the battery for 10 seconds, then
the battery voltage is read. If the battery voltage is too low, then
the console will indicate "BATTERY LOW". If this happens,
make sure that the battery is connected and that the Battery fuse
(F5) is good. The "BATTERY LOW" indication will remain until
the next battery test is run, 1 hour later, or when a Show Test
command is given.
- COMMUNICATOR TRBL NOW: Indicated if the digital
communicator (not the voice dialer) was unable to make contact
with the Central Station after trying both numbers multiple times.